2160 Wh LFP-based portable energy system with wheeled cart form factor. Supports solar charging up to 800 W, AC & USB output, UPS switching ≤10 ms, built-in aerosol fire suppression, and parallel expansion for up to 5 units. Rated IP65, IK09.

2160 WhRated Capacity
2000 WMax Output
IP65Protection
≤10 msUPS Switchover
LFP BatteryIP65 / IK09UPS FunctionSolar Ready — 800 WFire SuppressionParallel × 5 Units≥2000 Cycles
Download Datasheet
KSP-0202
Note: Output power is 2000 W at 0 °C~45 °C and 1000 W at −20 °C~0 °C. The built-in aerosol fire suppression activates automatically when internal temperature exceeds 180 °C.
Technical Specifications
ParameterValue
General
ModelKSP-0202
Rated Capacity2160 Wh
Rated Output Power2000 W (0 °C~45 °C) / 1000 W (−20 °C~0 °C)
Conversion Efficiency≥95%
Charging Time~3 hours (at 25 °C)
Weight~41 kg
Dimensions (L × W × H)649 × 431 × 452 mm
Battery ChemistryLFP (Lithium Iron Phosphate)
IP RatingIP65
Impact ResistanceIK09
UPS Switchover Time≤10 ms
AC Output
Outlet Type125 V Grounded 2-Pin × 2
Rated Output Voltage100 VAC ±4%
Frequency50 Hz / 60 Hz
Rated Output Current20 A
Per Port Output Current20 A
Overload Protection≤125%: Continuous | 125%~130%: After ~1 min | ≥130%: After ~500 ms
DC Output (USB)
Port ConfigurationUSB-A × 1 & USB-C × 1
Output Voltage / Max Power5 / 9 / 12 VDC, max 18 W per port
AC Input (AC Charging)
Input Voltage100 VAC ±10%
Max Input Current≤10 A
PV Input (Solar Charging)
Input Voltage Range12~60 VDC
Max Input Current≤15 A
Max Charging PowerUp to 800 W
Parallel Operation
Parallel Port Current20 A
Parallel Quantity2 units (parallel cable) / 3~5 units (expansion connector)
Operating Environment
Charging Temperature0 °C~45 °C
Storage Temperature−20 °C~45 °C
Storage Humidity≤75% RH (non-condensing)
Cycle Life≥80% capacity after 2000 cycles @ 25 °C
Long-Term Storage−10 °C~25 °C: 6 months | −20~−10 °C / 25~45 °C: 3 months
Battery Specifications
Rated Battery Voltage48 VDC
Output Voltage Range40~54.3 VDC
Battery Capacity45 Ah @ 25 °C (≥95% @ 55 °C; ≥70% @ −10 °C)
Charging Time~3 hours @ 25 °C
Discharge Power Limit≤1000 W (−20 °C~0 °C) / ≤2000 W (0 °C~45 °C)
Fire Suppression System
Extinguisher Units2 × aerosol-type fire extinguishing units
Extinguishing PrincipleOxygen isolation
Activation TriggerInternal temperature > 180 °C (automatic)